Clinical Trials Press Articles
The use of electronic spirometers for home data collection in respiratory clinical trials


Chronic lung diseases such as asthma and chronic obstructive pulmonary disease (COPD) are increasing in prevalence throughout the world and finding effective drug treatments to help sufferers is of great interest to many pharmaceutical companies. Lung function measurements provide objective data that can demonstrate the effectiveness of these new therapies and measurements of either peak expiratory flow (PEF) and or forced expiratory volume in one second (FEV1) are often primary endpoint outcome measures. The collection of good quality data is therefore a critical factor to the success of most respiratory trials.


 Home collection of PEF and symptom scores in asthma studies has been  widely practiced for many years but with the recent emergence of new treatments specifically for COPD  there is an increasing need to focus on symptom scores and to replace PEF measurement with FEV1.  COPD is a chronic condition with less demonstrable improvement in lung function and FEV1 is considered a  more reproducible, accurate measure to show clinically significant changes. Mechanical peak flowmeters  and paper diaries have been used to record daily PEF and symptom data, the accuracy of which has long  been suspected as being inaccurate and indeed falsification of records has been clearly demonstrated in  independent studies (1). Such a mechanical meter is also limited to the measurement of peak flow, and  FEV1, has been limited largely to clinic spirometry measurement.


 The use of modern electronic spirometers specifically designed to provide an alternative to mechanical  PEF meters and paper diary cards is therefore of great interest to pharmaceutical companies as a way to  maximise objective data collection when monitoring drug responses at home. Such devices use different  measurement sampling principles so that FEV1 as well as PEF can be accurately measured. Some of these  devices have memory storage so that every recorded blow is electronically stored and date and time  stamped and some also have the possibility to record symptom data responses in the same unit.


 Every pharmaceutical company wants to reduce the length of time in getting a drug to market and  increasingly electronic data transfer is seen as a possible solution to reducing this time, making devices  such as these electronic spirometers very attractive to use. The increased cost when using electronic  spirometers over mechanical peak flow meters has often been prohibitive to using such devices in the  past but it is now more widely accepted that the additional time saved in data transfer and the speedy  presentation of clean data when using such devices can significantly reduce the overall cost of a clinical  trial.


 Due to the array of electronic spirometers available, companies need to take into account some important  factors when considering the choice of such a device. Studies have shown ease of use to be an  important factor in helping with compliance of home monitoring in respiratory trials (2). Modern technology  can be perceived as difficult to use, particularly in elderly patients typical of the subject group being  studied in COPD trials and a user-friendly device is of key importance. The ability to ask questions about  symptoms that can be viewed in the patient’s own language and answered in the same device is also very  important in both COPD and asthma trials.


 PEF and FEV1 are both effort dependant manoeuvres and in the case of FEV1, duration of blow is critical  to get a good quality blow. The addition of quality check messages that can be viewed by patients when  recording PEF and FEV1 unsupervised at home is particularly helpful in obtaining good quality data and  some electronic spirometers also incorporate this feature. The measuring technology for reproducible  performance of electronic PEF/FEV1 meters should be proven to be stable and accurate without the need  for daily calibration, which is not practical in a home setting, and a turbine device is ideal in this situation.  Any spirometer that is chosen must be compliant to the 1994 ATS spirometry manufacture standards for  monitoring and diagnosis in respiratory disease.


 Other considerations, such as the amount of memory space and the option to have audible reminder and  warning alarms are important, particularly in asthma studies, when there can be several weeks between  clinic visits and lung function can suddenly deteriorate. Finally, the method by which data is tranferred  from the device is of great importance to the overall success of any study using electronic data capture  and should be easy for use investigators and monitors to use. In addition data managers must be happy  that all uploaded data is secure and readily transferrable into their study database. Spending time  choosing an electronic PEF/FEV1 meter that meets all these needs and discussing the criteria for data  transfer is time well spent in the initial planning stages. Pharmaceutical companies should consider inviting  companies who specialise in the manufacture of spirometers to partake in discussions with study  managers and data managers at the protocol planning stage when a clear understanding of how these  devices will work successfully in practice can be decided.


 Author: Gill Rowe
 Job Title: New Business Development Manager
 Micro Medical Ltd
 Quayside
 Chatham Maritime
 Kent
 ME4 4QX
 United Kingdom
 T +44 (0)1634 893500
 F +44 (0)1634 893600
 Email pharmasales@micromedical.co.uk
 Website www.micromedical.co.uk


  Back
 
 